Sierra Olympic Technologies Inc.

IRCameras

Mid Wave IRC800

The IRC800 Series cameras offer the ultimate in flexibility for research scientists. Camera operators can vary integration times, frame rates and cold filters to meet the most precise testing requirements making the IRC800 the perfect instrument for prototyping system development or where application requirements may change.

A 1/3-liter LN2 pour-filled Dewar assembly maintains temperature for up to 20 hours unpowered and 9 hours powered which makes the IRC800 Series perfect for Scientific Imaging, Process Analysis and Quality Assurance. 

FEATURES

Utilizing the most advanced Indium Antimonide (InSb) focal plane array technology available, the LN2 cooled IRC800 Mid Wave Series features unmatched sensitivity, ultra-low noise, no blooming and no crosstalk. The IRC800 Series can be calibrated for accurate temperature measurement, and our powerful Thermography SuiteTM image acquisition and analysis software allows users to obtain temperature calibrated data necessary for making critical decisions.

The IRC800 Series cameras offer the ultimate in flexibility for researchers and scientists. Camera operators can vary integration time, frame rate and window size. Cold filters can be changed making the camera ideal for spectrally dependent applications. The IRC800 is the perfect instrument for prototyping system development or where application requirements may change. Simultaneous Camera Link, GigE and HDMI outputs are standard.

Super-framing allows the cameras to switch among different integration times on a frame by frame basis to capture rapidly changing scenes over a wide dynamic range.  There are 4 standard models of the IRC800 based on the pour filled LN2 Dewar Assembly. All of the infrared cameras offer a digital Indium Antimonide (InSb) focal plane array (FPA) and your choice of 320×256, 640×512 or 1280×1024 format sensors.  See Optics/Sizes chart for more details. 

  • Choice of LN2 cooled InSb sensors
  • <1 μm to >5 μm spectral response
  • NEdT <20mK typical
  • SuperFraming for extended dynamic range
  • Motorized four position filter wheel option
  • High frame rates & windowing

APPLICATIONS

Spectroscopy

  • Scientific research
  • Quantitative analysis

Chemical Analysis

  • Precise testing
  • Process analysis

Material Evaluation

  • Research & development
  • Prototyping system development

MODELS


Product
Resolution
Pixel Pitch
Frame Rate
NEdT
Well Capacity
Operability
 
IRC803
320 x 256
30 μm
478 Hz
17 mK/25 mK
20 M/4 M
99.8 %
IRC806
640 x 512
20 μm
119 Hz
18 mK
7 M
99.8 %
IRC806HS
640 x 512
20 μm
478 Hz
18 mK
7 M
99.8 %
IRC812
1280 x 1024
12 μm
119 Hz
< 30 mK
2 M
99.6 %

SPECIFICATIONS

Detector
                                                                                                             
Detector type Indium Antimonide (InSb)
Spectral response < 1.0 μm to 5.3 μm
Resolutuion Varies by model, see optics/sizes tab
Pixel Pitch Varies by model, see optics/sizes tab
Imaging Electronics
                                                                                                             
Frame rate Varies by model, see optics/sizes tab
Integration time <150ns to full frame time Dynamic range
Dynamic range 14-bit w/ 13-bit option (increases frame rate at small window sizes)
Windowing User defined in 4x1 increments; min width=320, min height=32
Integration type Snapshot, automatic selection of integrate while read or integrate then read
Ultra low latency sync Sync I/O, integration out
Image data Simultaneous Camera Link, GigE & HDMI
Communications Serial over Camera Link & GigE
Software control Cross platform GenICam compliant
Image data stamp Optional IRIG, GPS with on-board receiver
Performance
                                                                                                             
Temp measure range -20˚ to 350˚ C standard, up to 2000˚ C optional
NEdT Varies by model, see optics/sizes tab
Well capacity (electrons) Varies by model, see optics/sizes tab
Operability Varies by model, see optics/sizes tab
LN2 hold time > 8 hrs typical, > 4 hrs w/ optional cold filter wheel
Optics
                                                                                                             
Camera f/# f/2.3 & f/4.0 standard; custom cold shields available
Cold filter 3.0 μm - 5.0 μm or no cold filter standard
* Cold Filter optional CO2, SWIR or custom filters on request
Lens mount Bayonet for 7, 13, 25, 50, 100 & 50/250 mm lenses
* Lens mount Bolt hole pattern for non-standard lenses
Optional filter wheel Motorized four position cold filter wheel; 25.4 mm diameter x 1.0 mm thick filters
General
                                                                                                             
Power @ 24 VDC 12 watts
System weight < 7 pounds
Size 3.7” x 8.1” x 11.8”
Operating temperature range -40° C to +55° C (-40° F to +131° F)
Storage temperature range -55° C to +80° C (-67° F to +176° F)
Environmental rating IP-51
Mounting holes 2x 1/4-20 & 4x #10-24

EXPORT

IMPORTANT EXPORT INFORMATION 

Coming Soon